DB-2887
DB-2887
- Capillary
제품 정보
- 100% Dimethylpolysiloxane
- Specifically designed for simulated distillation using ASTM Method D 2887
- Rapid conditioning, fast run time and low bleed when compared to packed columns
- Bonded and cross-linked
Solvent rinsable - Each Agilent J&W GC column is tested with the tightest industry QC specifications for column bleed, sensitivity, and efficiency to provide you utmost confidence in qualitative and quantitative results
- For details about the QC test conditions including the test probe mixture and the resulting chromatogram, please refer to the Agilent J&W GC Column Performance Summary shipped with each GC column
Similar Phases: Petrocol EX2887, MXT-2887, MXT-1, Rtx-2887
Megabore | |
ID (mm) | 0.53 mm |
Length (m) | 10 m |
Film (µm) | 3.00 µm |
Temperature Limits (°C) | -60 - 350 °C |
- 주요 참고문헌
-
Analysis of Free and Total Glycerol and Triglyceride Content in B-100 Biodiesel Methyl Esters Using Agilent Select Biodiesel for Glycerides
Application note for the analysis of Free and Total Glycerol and Triglyceride Content in B-100 Biodiesel Methyl Esters Using Agilent Select Biodiesel for Glycerides
- 응용 자료
- English
- 12 Feb 2014
- 475.91 KB
Analysis of Carcinogenic Tobacco- Specific Nitrosamines in Mainstream Cigarette Smoke Using an Agilent J&W DB-35ms Ultra Inert GC Column
A simple and sensitive method for routine analysis of tobacco-specific nitrosamines in mainstream cigarette smoke was developed
- 응용 자료
- English
- 01 Aug 2013
- 348.85 KB
Determination of Total FAME and Linolenic Acid Methyl Esters in Biodiesel According to EN-14103
Explaining GC methods of determining whether biodiesel conforms to the standard specifications.
- 응용 자료
- English
- 26 Sep 2012
- 184.79 KB
Determination of Methanol Content in Biodiesel Using Agilent Select Biodiesel for Methanol with Headspace Sampling to EN-14110
Application note for the determination of Methanol Content in Biodiesel Using Agilent Select Biodiesel for Methanol with Headspace Sampling
- 응용 자료
- English
- 12 Feb 2014
- 401.31 KB
- 카탈로그
Save time - use our online GC column selection tool to find the right GC column for your application in just a few clicks!
www.agilent.com/chem/selectGC
The Agilent GC Method Translation Software allows you to port a current GC method to another while ensuring that relative retention order is maintained.
Unsure which vials and closures are best suited to your application?
Quickly and easily find the perfect match using our selection tool: www.agilent.com/chem/SelectVials
GC 컬럼 설치 동영상 - GC 문제 해결 시리즈
- 00:16:50
GC 컬럼의 기초
- 00:15:56
GC 연결 향상
- 00:04:27