CP-Select 624 CB
CP-Select 624 CB
- Capillary
제품 정보
- Guaranteed for EPA volatiles with methods 524.2, 624 and 8015 for maximum confidence
- Specified by Pharmacopoeia method V.3.3.9 for residual solvent analysis, providing compliancy
- Excellent column-to-column reproducibility
- Low bleed
- Each Agilent J&W GC column is tested with the tightest industry QC specifications for column bleed, sensitivity, and efficiency to provide you utmost confidence in qualitative and quantitative results
- For details about the QC test conditions including the test probe mixture and the resulting chromatogram, please refer to the Agilent J&W GC Column Performance Summary shipped with each GC column
Configuration choices for Agilent J&W CP-Select 624 CB
Capillary | |
ID (mm) | 0.15 – 0.32 mm |
Length (m) | 25 – 60 m |
Film (µm) | 0.84 – 1.80 µm |
Temperature Limits (°C) | 265/280 °C |
Megabore | |
ID (mm) | 0.53 mm |
Length (m) | 30 – 105 m |
Film (µm) | 3.00 µm |
Temperature Limits (°C) | 265/280 °C |
- 응용 자료
-
Solvents - Separation of solvent acetate esters
Gas chromatography with an Agilent J&W CP-Select 624 CB column separates 18 solvent acetate esters in 20 minutes.
- 응용 자료
- English
- 19 Jul 2017
- 520.92 KB
Alcohol in blood
Head space analysis of alcohols in blood with FID, using an Agilent J&W CP-Select 624 CB column, is accomplished in 2.5 minutes.
- 응용 자료
- English
- 13 Jan 2017
- 484.87 KB
The Analysis of Volatile Organic Compounds in Air and/or Soil Gas
To achieve method detection limits for volatile organic compounds (sub ppb) in air, sample concentration before analysis on Agilent J&W CP-Select 624 is needed.
- 응용 자료
- English
- 10 Jun 2014
- 1.26 MB
The Determination of Volatile Organic Compounds in Ambient Air
A gas chromatograph with a built in cryogenic concentrator and Agilent J&W CP-Select 624 CB column separates ten volatile organic compounds in a sample of ambient air.
- 응용 자료
- English
- 10 Jun 2014
- 2.19 MB
Volatile Organic Compounds in Water by Purge and Trap/Capillary Column Gas Chromatography with Photoionization (PID) and Electrolytic Conductivity Detectors (ELCD) in Series
An Agilent J&W CP-Select 624 column and gas chromatography separates 38 volatile organic compounds in water using PID and ELCD detectors.
- 응용 자료
- English
- 10 Jun 2014
- 1.25 MB
Solvents
Gas chromatography with an Agilent J&W CP-Select 624 CB column separates nine solvents in 18 minutes.
- 응용 자료
- English
- 06 Jun 2014
- 803.13 KB
Solvents
Gas chromatography using an Agilent J&W CP-Select 624 CB column separates 36 solvents in 41 minutes.
- 응용 자료
- English
- 06 Jun 2014
- 1.08 MB
FAME
Gas chromatography of fatty acid methyl esters in partially hydrogenated soybean oil with an Agilent J&W CP-Select CB for FAME column separates 21 FAMEs in 30 minutes.
- 응용 자료
- English
- 29 May 2014
- 67.45 KB
FAME
Gas chromatography of fatty acid methyl esters in bean oil separates 12 FAMEs in 24 minutes using an Agilent J&W CP-Select CB for FAME column.
- 응용 자료
- English
- 29 May 2014
- 699.48 KB
FAME
Gas chromatography of fatty acid methyl esters in butter separates 20 FAMEs in less than 17 minutes using an Agilent J&W CP-Select CB for FAME column.
- 응용 자료
- English
- 29 May 2014
- 825.39 KB
- 카탈로그
- 인용
- 홍보자료
Save time - use our online GC column selection tool to find the right GC column for your application in just a few clicks!
www.agilent.com/chem/selectGC
The Agilent GC Method Translation Software allows you to port a current GC method to another while ensuring that relative retention order is maintained.
Unsure which vials and closures are best suited to your application?
Quickly and easily find the perfect match using our selection tool: www.agilent.com/chem/SelectVials
GC 컬럼 설치 동영상 - GC 문제 해결 시리즈
- 00:16:50
GC 컬럼의 기초
- 00:15:56
GC 연결 향상
- 00:04:27