CP-Simulated Distillation UltiMetal
CP-Simulated Distillation UltiMetal
- Capillary
제품 정보
- Designed for ASTM D2887 and the extended D2887 method compliance
- Low bleed
- Extended analysis to C120 with maximum temperature of 450 °C
- UltiMetal tubing for excellent durability (same id as 0.53 mm id fused silica)
- Excellent retention time repeatability and column lifetime due to special deactivation of UltiMetal surface
- Each Agilent J&W GC column is tested with the tightest industry QC specifications for column bleed, sensitivity, and efficiency to provide you utmost confidence in qualitative and quantitative results
- For details about the QC test conditions including the test probe mixture and the resulting chromatogram, please refer to the Agilent J&W GC Column Performance Summary shipped with each GC column
Similar Phases: Petrocol EX2887, MXT-2887, Rtx-2887, AC Controls High Temp Sim Dist, AT-2887, ZB-1XT SimDist
Megabore | |
ID (mm) | 0.53 mm |
Length (m) | 5 - 25 m |
Film (µm) | 0.06 - 5.00 µm |
Temperature Limits (°C) | 400/400 °C (2.65, 5.00 µm) |
450/450 °C (0.06 - 1.20 µm) |
- 응용 자료
-
Triglycerides C24-C54
Gas chromatography using an Agilent J&W CP-SimDist UltiMetal column separates C24 to C54 triglycerides in 40 minutes.
- 응용 자료
- English
- 13 Jun 2014
- 643.18 KB
Hydrocarbons C12 – C44
Gas chromatography with an Agilent J&W CP-SimDist UltiMetal column analyzes a sample of mineral oil in 50 minutes.
- 응용 자료
- English
- 04 Jun 2014
- 598.65 KB
Fatty acid ethylene glycol esters C16 – C36
Gas chromatography with an Agilent J&W CP-SimDist UltiMetal column separates fatty acid ethylene glycol esters in a sample of montan wax in 36 minutes.
- 응용 자료
- English
- 30 May 2014
- 569.41 KB
FAME C12 - C54
Dimeric fatty acids care determined by GC as methyl esters on a high temperature, stable thin-film polydimethylsiloxane Agilent J&W CP-SimDist UltiMetal, in 25 min.
- 응용 자료
- English
- 28 May 2014
- 415.93 KB
Extended simulated distillation of motor oil
Extended simulated distillation of a ‘polluted’ motor oil according to D2887 with an Agilent J&W CP-SimDist UltiMetal column.
- 응용 자료
- English
- 27 May 2014
- 1.06 MB
Extended simulated distillation of motor oil
Extended simulated distillation of a motor oil according to D2887 with an Agilent J&W CP-SimDist UltiMetal column.
- 응용 자료
- English
- 27 May 2014
- 1.49 MB
Hydrocarbons C3 – C120
Gas chromatography and an Agilent J&W CP-SimDist UltiMetal column separate hydrocarbons according to IP PM-CX/98.
- 응용 자료
- English
- 04 Nov 2013
- 955.65 KB
Sulfur compounds
Gas chromatography with an Agilent J&W CP-SimDist Ultimetal column separates 13 C12 to C60 waxes plus a sulfur standard in 16 minutes.
- 응용 자료
- English
- 04 Nov 2013
- 501.29 KB
Hydrocarbons C18 – C90
Gas chromatography with an Agilent J&W CP-SimDist UltiMetal column separates C18 to C90 hydrocarbons in a heavy wax sample in 44 minutes.
- 응용 자료
- English
- 04 Nov 2013
- 1.02 MB
Save time - use our online GC column selection tool to find the right GC column for your application in just a few clicks!
www.agilent.com/chem/selectGC
The Agilent GC Method Translation Software allows you to port a current GC method to another while ensuring that relative retention order is maintained.
Unsure which vials and closures are best suited to your application?
Quickly and easily find the perfect match using our selection tool: www.agilent.com/chem/SelectVials
GC 컬럼 설치 동영상 - GC 문제 해결 시리즈
- 00:16:50
GC 컬럼의 기초
- 00:15:56
GC 연결 향상
- 00:04:27