Skip to main content

InfinityLab Poroshell 120 Resources

Please see below selected technical and applications notes relating to InfinityLab Poroshell 120 columns. Check back often to see new applications as they become available.

Technical Notes

Instrument, Method, and Sample Optimizations to Get the Most from Agilent InfinityLab Poroshell 120, 1.9 µm Columns (publication #5991-7560EN)

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography (publication #5991-8602EN)

Achieve Ultrafast Separations with Agilent Poroshell 120 EC-C18, 1.9 µm Columns (publication #5991-7540EN)

Low and High pH Stability of Agilent Poroshell HPH C18 (publication #5991-6525EN)

Easy Method Transfer and Improved Performance with Poroshell 120 4 µm Columns (publication #5991-5510EN)

Use of Poroshell HPH-C18 Columns at Elevated pH as a Tool for Method Development (publication #5991-4893EN)

Extending Column Lifetime in Pharmaceutical Methods with High pH-Stable Poroshell HPH Chemistries (publication #5991-5022EN)

Maximizing the Efficiency of Poroshell 120 Columns (publication #5990-5602EN)

Transfer of Methods between Poroshell 120 EC-C18 and ZORBAX Eclipse Plus C18 Columns (publication #5990-6588EN)

Application Notes

Food

Analysis of Water-soluble Vitamins on an Agilent InfinityLab Poroshell 120 HILIC-OH5 Column (publication #5991-8780EN)

Methods for the Analysis of Underivatized Amino Acids by LC/MS (publication #5991-8582EN)

Separation of 10 Green Tea Components on an Agilent InfinityLab Poroshell 120 EC-C18, 1.9 µm Column (publication #5991-7542EN)

LC/MS Analysis of Free Amino Acids on Agilent InfinityLab Poroshell 120 HILIC 1.9 µm Columns (publication #5991-7541EN)

Screening and Verifying Mycotoxins in Food with Q-TOF LC/MS and an Accurate Mass Library (publication #5991-5667EN)

Automated Amino Acid Analysis Using a Poroshell HPH-C18 Column (publication #5991-5571EN)

Determination of Sulfonamide Residues in Milk with Agilent Captiva ND Lipids Filtration and LC/MS/MS  (publication #5991-2230EN)

Fast Determination of N-Methyl Carbamate Pesticides in Fruit and Vegetable Juice (publication #5991-2124EN)

Fast Analysis of Fruit Juice Acids with an Agilent Poroshell 120 SB-Aq Column (publication #5991-1992EN

LC/MS/MS Analysis of Fungicides and Metabolites in Apple Juice by Bond Elut Plexa and Poroshell 120 (publication #5991-0051EN)

Selectivity Comparison of Poroshell 120 Phases in the Separation of Butter Antioxidants (publication #5991-1897EN)

Fast Separation of Food Preservatives Using an Agilent Poroshell 120 EC-C18 Column (publication #5991-1898EN)

Modified QuEChERS for HILIC LC/MS/MS Analysis of Nicotine and its Metabolites in Fish (publication #5991-2408EN)

Analysis of color additives in sweets (publication #5990-9525EN)

Fast, Low Pressure Analysis of Food and Beverage Additives Using a Superficially Porous Agilent Poroshell 120 EC-C18 Column (publication #5990-6082EN)

Profiling capsaicinoids in spicy foods and food products using the Agilent 1290 Infinity LC system and Agilent ZORBAX Poroshell 120 2.7 μm columns with UV/Vis diode array and fluorescence detection (publication # 5990-5992EN)

Transfer and Optimization of Existing Methods for Analysis of Antibiotics in Meat to Agilent Poroshell 120 EC-C18 Columns using MS/MS Detection (publication #5990-6238EN)

Determination of Hormones in Shrimp by Agilent 1290 Infinity LC with Agilent Poroshell 120 LC Column and Agilent QuEChERS for Sample Preparation (publication #5990-6589EN)

Analysis of Pesticide Residues in Green Tea Using Agilent SampliQ QuEChERS EN Kit by LC/MS/MS Detection (publication #5990-6400EN)

Fast Analysis of Sulfa Drugs using the Agilent 1100 Series LC with Agilent Poroshell 120 EC-C18 columns (publication #5990-5572EN)

Rapid Tea Analysis on Poroshell 120 SB-C18 with LC/MS (publication #5990-7824EN)

Analysis of water-soluble vitamins from multivitamin tablets for nutrition labeling (publication #5990-7950EN)

Analysis of ascorbic acid, citric acid and benzoic acid in orange juice (publication #5990-8720EN)

Analysis of fat soluble vitamins from food matrix for nutrition labeling (publication #5990-8668EN)

Analysis of Pesticide Residues in Rice Using Agilent Bond Elut QuEChERS AOAC Kit (publication #5990-8034EN)

LC/MS/MS Analysis of Malachite Green (MG) and Crystal Violet (CG ) in fish with Agilent Bond Elut PCX and Poroshell 120 (publication #5991-0091EN)

Fast Separation of Synthetic/Artificial Food Colors on Agilent Poroshell 120 EC-C18 (publication #5991-0816EN)

Aminoglycosides in Bovine Muscle Using Bond Elut Plexa SPE, Poroshell 120 and LC/MS (publication #5991-1321EN)

Analysis of Water Soluble Vitamins in Multivitamins Using Poroshell 120 (publication #5990-8107EN)

Analysis of Anthocyanins in Common Foods Using an Agilent Poroshell 120 SB-C18 (publication #5990-8249EN)

Pharmaceutical

Analysis of Aminoglycosides Using the Agilent InfinityLab Poroshell 120 HILIC-Z Column (publication #5991-8824EN)

Separation of Beta Blockers at low and high pH using Poroshell HPH C18 (publication #5991-6519EN)

Adapt the USP Naproxen Tablet Method for an Agilent Poroshell 120 EC-C18, 4 µm Column (publication #5991-5408EN)

Method Development for USP Related Compounds in Paclitaxel using Poroshell 120 PFP (publication #5991-6283EN)

Faster Analysis of Naproxen Using Poroshell 120 EC-C18: Headache Free Method Adjustment (publication #5990-7456EN)

Fast Analysis of Cefepime and Related Impurities on Poroshell 120 EC-C18 (publication #5990-7492EN)

Transfer of Methods between Poroshell 120 EC-C18 and ZORBAX Eclipse Plus C18 Columns (publication #5990-6588EN)

Analysis of Water Soluble Vitamins in Multivitamin Tablets Using Poroshell 120 EC-C18 (publication #5990-8107EN)

Converting a CHP Method for Insulin to Agilent Poroshell 120 Columns (publication #5990-9029EN)

Analysis of Echinacoside and Verbascoside in Cistanche deserticola Chinese Medicine Using an Agilent Poroshell 120 EC-C18 (publication #5990-9633EN)

Faster LC Analysis of Notoginseng Total Saponins Using an Agilent Poroshell 120 EC-C18 (publication #5990-9632EN)

USP Analysis of Norethindrone and Metranol Tablets with Agilent Poroshell 120 EC-CN and EC-C8 (publication #5991-1688EN)

USP Analysis of Diphenhydramine and Pseudoephedrine Using an Agilent Poroshell 120 EC-CN Column (publication #5991-1687EN)

USP Analysis of Warfarin Sodium Tablets Using Agilent Poroshell 120 EC-CN and SB-C8 Columns (publication #5991-1686EN)

Fast Screening Methods for Steroids by HPLC with Agilent Poroshell 120 Columns (publication #5991-0451EN)

LC/ELSD and LC/MS/MS of Cholesterol and Related Sterols on a Poroshell 120 Column (publication #5991-0452EN)

Transfer the USP Method for Ceftizoxime from a Traditional 5-um Column to an Agilent Poroshell 120 (publication #5991-3717EN)

Modernizing the USP Monograph for Acetaminophen (publication #5991-3579EN)

Modernizing the USP Monograph for Impurity Profiling of Metoprolol Tartrate (publication #5991-4564EN)

Sample Prep for Trace Analysis of Adulterants in Erectile Dysfunction Dietary Supplements (publication #5991-3638EN)

Environmental

Improved EPA-8330A Analysis with Agilent Poroshell 120, 1.9 µm Columns (publication #5991-7538EN)

Determination of hormones in Drinking Water by LC/MS/MS (publication #5991-6995EN)

Carbonyl-DNPH Derivatives in Indoor and In-car Air by UHPLC and Triple Quadrupole LC/MS (publication #5991-2125EN)

Isolation, Purification and Chromatography of Nitro Compounds and Explosives (publication #5990-5552EN)

Fast Analysis of Environmental Phenols with Agilent Poroshell 120 EC-C18 Columns (publication #5990-6156EN)

Fast Analysis of Hair Dyes Using an Agilent Poroshell 120 EC-C18 Column (publication #5990-6501EN)

Trace analysis of explosives in soil samples using the Agilent 1290 Infinity LC System equipped with an Agilent Max-Light 60-mm cartridge cell (publication #5990-6817EN)

Analysis of EU banned Azo colorants in textiles using Poroshell 120 and 1290 Infinity (publication #5990-7705EN)

EPA 8330A Analysis of Explosives Using Agilent Poroshell 120 EC-CN and EC-C18 Columns (publication #5991-1682EN)

Forensics

Separation of Eight Benzodiazepines on an Agilent Poroshell 120 EC-C18, 1.9 µm Column (publication #5991-7539EN)

Analysis of Drugs of Abuse at Low and High pH using Agilent Poroshell HPH C18 by LCMS (publication #5991-6523EN)

Analysis of Tricyclic Antidepressants using Agilent Poroshell HPH C18 (publication #5991-6512EN)

Analyze Barbiturates in Urine with Agilent 6430 LC/MS/MS and Poroshell 120 EC-C18 (publication #5991-2596EN)

Fast Analysis of Illicit Drug Residues on Currency using Agilent Poroshell 120 (publication #5990-6345EN)

SAMHSA-Compliant LC/MS/MS Analysis of Amphetamines in Urine with Agilent Bond Elut Plexa PCX and Agilent Poroshell (publication #5990-9623EN)

SAMHSA-Compliant LC/MS/MS Analysis of Benzoylecgonine in Urine with Agilent Bond Elut Plexa PCX and Agilent Poroshell (publication #5990-9624EN)

SAMHSA-Compliant LC/MS/MS Analysis of Opiates (Morphine and Codeine) in Urine with Agilent Bond Elut Plexa PCX and Agilent Poroshell 120 (publication #5990-9625EN)

SAMHSA-Compliant LC/MS/MS Analysis of Phencyclidine in Urine with Agilent Bond Elut Plexa PCX and Agilent Poroshell 120 (publication #5990-9626EN)

SAMHSA-Compliant LC/MS/MS Analysis of 11-nor-9-carboxy-D9-Tetrahydrocannabinol in Urine with Agilent Bond Elut Plexa PCX and Agilent Poroshell 120 (publication #5990-9627EN)

LC/MS/MS of Buprenorphine and Norbuprenorphine in Whole Blood Using Agilent Bond Elut Plexa PCX and an Agilent Poroshell 120 Column (publication #5990-9930EN)

Hydrophilic Interaction Chromatography (HILIC) Using Agilent Poroshell 120 HILIC (publication #5991-1242EN)

Fast Screening Methods for Steroids by HPLC with Agilent Poroshell 120 Columns (publication #5991-0451EN)

Consumer Products

Analysis of hair dyes using InfinityLab Poroshell HPH-C18 4 µm Columns (publication #5991-7436EN)

Fast Analysis of Hair Dyes at High pH with Agilent Poroshell HPH-C18 and Other Phases (publication #5992-5263EN)

Agilent 1290 Infinity LC with Agilent Poroshell columns for simultaneous determination of eight organic UV filters in under two minutes (publication #5990-6861EN)

Fast Analysis of Hair Dyes Using Agilent Poroshell 120 Bonus-RP Column by UHPLC and LC/MS/MS (publication #5991-1289EN)

Traditonal Chinese Medicine

Fingerprint Profiling of Extracts from Danshen Using Sub-2 µm Superficially Porous LC Columns (publication #5991-7559EN)

Analysis of Saponins in Notoginseng using Poroshell 120, 4 µm columns (publication #5990-5554EN)

Analysis of Danshen (Salvia Miltrorrhiza) and Compound Danshen Dropping Pills using Poroshell 120 Superficially Porous LC Columns (publication #5990-5739EN)

Quantitation of Stachydrine in Chinese Motherwort (Leonurus japonicus) by HILIC (publication #5991-8617EN)

Fast method for Ginseng Analyses using Agilent Poroshell 120 Columns Scaled from a Traditional Method (publication #5990-6843EN)

«

Back to InfinityLab Poroshell 120