1290 Infinity II LC System
1290 Infinity II LC System
The 1290 System embodies the next generation of ultra HPLC, with the exceptional reliability and robustness you expect from Agilent, plus breakthrough UHPLC technologies, to achieve unmatched separation and detection performance.
- Analytical HPLC Systems
Request a Quote
Product Details
- More chromatographic resolution from specially designed components in the sample flow path to achieve the lowest system dispersion
- Higher peak capacity for challenging separations - switch easily between single dimension high-end UHPLC and the ultimate chromatographic power of 2D-LC
- Lower carryover for uncompromised data quality - multiwash capabilities of the Agilent 1290 Infinity II Multisampler reduce carryover to less than 10 ppm even for challenging compounds such as chlorohexidine
- Unique detection capabilities - combine lowest detection limits with an ultrawide dynamic range by using the new Agilent 1290 Infinity II HDR-DAD or 1290 Infinity II ELSD
- Faster injection cycles with dual-needle injection - for higher sample throughput
- Higher sample capacity per bench space - up to 6144 samples within the footprint of a standard Agilent stack
- Flexibility for all applications - through wide power, temperature, an automatically scalable injection range, and gradient options
- Seamless transfer of methods between LCs, regardless of the brand - facilitated by intelligent system emulation technology (ISET) delivering unchanged retention time and peak resolution
- Seamless integration in your chromatography data system - Agilent InfinityLab LC instrumentation runs smoother when controlled through third-party chromatography data systems such as Waters Empower or Thermo Scientifics Chromeleon using the Agilent instrument control framework (ICF)
- Lower total cost of ownership - select from a variety of tools to achieve lowest cost-per-sample
- Your choice for performance and sustainability: The 1290 Infinity II LC System has received the My Green Lab ACT (Accountability, Consistency, Transparency) label after an independent audit to verify its environmental impact throughout the product life cycle.
Column Capacity |
|
Column ID Reader Option |
|
Depth |
|
Flow Range |
|
Injection Range |
|
Intelligent System Emulation Technology |
|
Line Voltage |
|
Maximum Number of Solvents |
|
Maximum Number of Temperature Zones |
|
Pump Type |
|
Special Features |
|
System Pressure Operating Range |
|
Width |
|
- Mobile Phase Delivery
-
1290 Infinity II Flexible Pump
Quaternary solvent delivery at pressures up to 1300 bar and flow rates up to 5 mL/min.
1290 Infinity II High Speed Pump
Binary solvent delivery at pressures up to 1300 bar and flow rates up to 5 mL/min.
- Sample Introduction
- Column Handling
- Detection
- Recommended Accessories
- Application Software
- Key Literature
-
LC Troubleshooting Guide
This poster will become the most helpful quick reference tool in your lab. It includes detailed information on how to overcome the most common troubleshooting issues.
- Posters
- English
- 15 Mar 2019
- 2.33 MB
Optimizing System Dispersion on the Agilent 1290 Infinity II LC
The 1290 Infinity II LC equipped with ultralow dispersion kit achieves significantly lower band-broadening than comparable UHPLC system from another vendor.
- Technical Overviews
- English
- 01 Aug 2018
- 921.11 KB
- Application Notes
- Brochures
- Flyers
- Posters
- Technical Overviews
- Quick Reference Guides
-
Agilent InfinityLab Supplies for the Agilent 1290 Infinity II LC with Multisampler
A list of the most commonly ordered supplies and parts for the 1290 Infinity II LC with Multisampler.
- Quick Reference Guides
- English
- 30 Oct 2018
- 269.60 KB
- Site Preparation Checklists
- Supplemental Information
- User Manuals
Read reviews on the 1290 Infinity II LC System
Explore customer reviews posted on SelectScience, or write your own review.
Agilent InfinityLab HPLC Advisor
This one comprehensive app provides tools and information for your daily HPLC workflow.
Dr. rer. Nat Tobias Minuth
Lower Saxony State Agency for Water Management, Coastal Defence and Nature Conservation - NLWKN - Hannover - Hildesheim, Dept. for Organic Trace Analysis
The PFAS measurement method was very time-saving and easy to establish, so that our routine procedures and the productivity of the laboratory could continue as usual and without disruptions. We were able to start routine measurement of more than 50 PFAS compounds in a very short time using the Agilent PFAS MRM database on our Agilent 1290 Infinity II/6495-QQQ system. The PFC-free HPLC elimination kit was easy to install and allowed us to significantly reduce PFAS blank values. Thanks to the collaboration with Agilent, we were able to provide our customers with a very reliable and highly accurate analysis of PFAS analytes in a very short time.
View MoreVideos
Seal of Quality Awarded to the Agilent 1290 Infinity II LC System
Agilent Technologies has achieved a Silver Seal of Quality for its 1290 Infinity II LC System. Seals of Quality by SelectScience recognize the top 0.1% of products that consistently receive the highest customer review ratings.
- Seal of Quality Awarded to the Agilent 1290 Infinity II LC System
- 25 Oct 2022
Agilent Announces Inspirational LC/TQ and LC/Q-TOF Mass Spectrometry Solutions at ASMS 2023
Agilent Technologies announced two new liquid chromatography mass spectrometry systems (LCMS), the Agilent 6495D LC/TQ and the Agilent Revident LC/Q-TOF. Facilitating the high-end performance of the Revident LC/Q-TOF, Agilent is also announcing the new Agilent MassHunter Explorer Profiling software and the new Agilent ChemVista library manager software.
- 05 Jun 2023