	ICP-MS MassHunter Workstation
	G7200A  Rev.A.02.01

	Copyright 1989 Agilent Technologies, Inc.
	All Rights Reserved
===================================================================
This file contains information on the following subjects:
	- New features
	- Minimum system requirements
	- File compatibilities
	- Known limitations

Also please refer to the Software Status Bulletins (SSB) in the SSB folder in the
system disc.


New features
-------------------------------------------------------------------
 - Add Isotope Ratio analysis function.
 - Expand Chromatographic data analysis functions.
 - Expand usability of various functions in Data analysis window.
 - Support Windows Vista.


Minimum System Requirements (tested configuration)
-------------------------------------------------------------------
In case of Windows Vista
 PC:		HP dc7900 Core2Duo 3GHz
 Memory:		2GB
 Hard drive:	250GB
 OS:		Windows Vista Business + Service Pack 1
 Excel:		Excel 2007 
 Internet Explorer:	Internet Explorer 7
 Printer: 		HP LaserJet 2420d, 4250, P3005d, P3005dn or later models
 Display:		Resolution 1600 x 1200 or 1680x1050
 I/O Libraries:	Agilent IO Libraries Suite 15.0
 ICP-MS:		Agilent 7500 Series (with LAN interface)
 LC/GC ChemStation: Co-existence with Agilent LC/GC ChemStation Rev B.04.01

In case of Windows XP
 PC:		HP dc7800 Core2Duo 2.33GHz
 Memory:		2GB
 Hard drive:	233GB
 OS:		Windows XP Professional + Service Pack 3
 Excel:		Excel 2007 
 Internet Explorer:	Internet Explorer 6 + Service Pack 1
 Printer: 		HP LaserJet 2420d, 4250, P3005d, P3005dn or later models
 Display:		Resolution 1600x1200
 I/O Libraries:	Agilent IO Libraries Suite 15.0
 ICP-MS:		Agilent 7500 Series (with LAN interface)
 LC/GC ChemStation: Co-existence with Agilent LC/GC ChemStation Rev B.04.01


File compatibilities
-------------------------------------------------------------------
Between G7200A Rev.A.02.01and Rev.A.01.01
    Analysis file		almost upward compatible (*note 1)
    Method file		same
    Data file		same
    Tune file		same
    Sequence file		same
    Chained Sequence file	same
    Report Template	file	almost upward compatible (*note 2)
    QC Mode file		same
    Script file		not compatible
*note 1:
         The below analysis file generated in Rev.A.01must be reprocessed 
         once in Rev.A.02.
            - Chromatogram data
            - Calibration curve converted from standard addition method
*note 2:
         Report Item; "LevelConcRSD" is renamed: "LevelRSD". 
         The report template which uses this item must be revised.

Between MassHunter (G7200A) and ChemStation (G1834A/B)
    Method  file		upward compatible
    Calibration file		not used, but can be imported into MassHunter.
    Data file		upward compatible (*note 1)
    Tune file		same
    Sequence file		upward compatible
    Chained Sequence file 	same
    Report Template file  	not compatible
    QC Mod file		not compatible
*note 1:
         MassHunter can not read G1834A/B ChemStation data files that 
         have been edited using the "Average File Editor" function of 
         ChemStation (If necessary, you can import data files from 
         ChemStation before editing, and reject any replicate data in the 
         MassHunter software).


Known Limitations
-------------------------------------------------------------------
- The LAN cable or serial cable connected to the autosampler should 
   not be removed or installed while MassHunter is running. 
   Do not turn off the auto sampler while the MassHunter is running.

- Agilent BootP Service (LAN model) is necessary.
   After this service has been installed, it is automatically started and 
   stopped along with Windows execution and shutdown. Do not stop or 
   disable this service manually.

- Screen savers and power management features of the PC BIOS and Windows
   should be disabled.  These can cause undue loading of the CPU that may 
   result in loss of data from the ICP-MS during busy data collection periods.

- Long file names cannot be used. When setting file names in MassHunter
  (data file names, method file names, sequence file names, chained sequence
   file names, QC mode files etc.,) or creating the folder in which 
  MassHunter is to be installed, use a maximum of 8 characters.

- If the data file folder currently being acquired is opened by another 
   application like Explorer, there is a possibility that Data Analysis will 
   generate an error when it analyzes the acquired data.

- To abort "Autotune", please use the "Abort" button on the Autotune
   Situation window. Do not click "Abort" on the system menu. 
   If "Abort" on the system menu is selected, the program may not finish
   correctly.

- Generating a batch report may take a protracted time (e.g. more than 
   a few hours). And it will fail if the PC resource (memory, CPU usage) 
   is insufficient. To generate a batch report, use the "Quick Batch Report" or 
   "Export Table" function and print it using Excel 2007.
 
- If the ROM version of the ASX500 software is ver.1.4 or earlier,
   the ASX500 may hang up when 0 sec is set for the "Rinse" or 
   when you stop a sequence that has already started. 
   To check the version, follow the steps listed below:
     1. Select "ASX500" in the autosampler box in the ICP-MS 
        Configuration screen.
     2. Click "Cmdline on" in the Acquisition system menu.
     3. Enter "ALSCOMMAND "VER"(ENTER-KEY)" in the command line.

- When cancelling a print job from the QC Tune Criteria or Sample Log Table, 
   the next print out is sometimes merged with the cancelled print out. 
   Printing should be executed again in this case.

- When using the User Access Control Pack, the ICP-MS MassHunter user
   accounts must have set a password. For security purposes users with 
   no password will not be able to logon to the ICP-MS MassHunter. 

-------------------------------------------------------------------